Option |
Values |
Description |
Model |
2416 |
1/16th DIN Base Model |
FUNCTION |
CC
CG
CP
P4
VC
VG
VP
V4
NF
NG
NP
N4 |
PID Controller
PID Controller with Single 8-Seg Program
PID Controller with Single 16-Seg Program
PID Control with Four Programs
Valve Position Control
Valve Position with Single 8-Seg Program
Valve Position with Single 16-Seg Program
Valve Position with 4 Programs
On/Off Controller
On/Off Controller with Single 8 Seg Programmer
On/Off Controller with Single 16 Seg Programmer
On/Off Controller with Four 16 Seg Programmer |
SUPPLY VOLTAGE |
VH
VL |
85 to 264Vac
20 to 29Vac/dc |
MODULE 1 |
R2
RH
RU
FH
FL
DB
DL
DH
L2
LH
M1
M2
T2
TH
TU
D2
H1
H2
H3
H4
H5
XX |
Single 2-Pin Relay Fitted Unconfigured
Relay PID Heating
Relay Valve Raise Output (With VC, VG, VP or V4)
Relay High Alarm 1
Relay Low Alarm 1
Relay Deviation Band Alarm 1
Relay Deviation Low Alarm 1
Relay Deviation High Alarm 1
Logic Output Fitted Unconfigured
Logic PID Heating
Logic Output PDSIO Mode 1
Logic Output PDSIO Mode 2
Triac Output Fitted Unconfigured
Triac PID Heating
Triac Valve Raise Output
DC Analog Output Fitted Unconfigured
0 to 20mA PID Heating
4 to 20mA PID Heating
0 to 5V PID Heating
1 to 5V PID Heating
0 to 10V PID Heating
None |
MODULE 2 |
R2
RC
RW
FH
FL
DB
DL
DH
PO
PE
L2
LC
T2
TC
TW
D2
C1
C2
C3
C4
C5
XX |
Relay Output Fitted Unconfigured
Relay PID Cooling
Relay Valve Lower Output (With VC, VG, VP or V4)
Relay High Alarm 2
Relay Low Alarm 2
Relay Deviation Band Alarm 2
Relay Deviation Low Alarm 2
Relay Deviation High Alarm 2
Relay Program Event O/P1
Relay Program End O/P
Logic Output Fitted Unconfigured
Logic PID Cooling
Triac Output Fitted Unconfigured
Triac PID Cooling
Triac Valve Lower Output
DC Analog Fitted Unconfigured
0 to 20mA PID Cooling
4 to 20mA PID Cooling
0 to 5V PID Cooling
1 to 5V PID Cooling
0 to 10V PID Cooling
None |
MODULE 3 |
R2
FH
FL
DB
DL
DH
RA
PO
PE
LF
HF
SF
L2
T2
D2
XX |
Relay Fitted Unconfigured
Relay High Alarm 4
Relay Low Alarm 4
Relay Deviation Band Alarm 4
Relay Deviation Low Alarm 4
Relay Deviation High Alarm 4
Relay Rate of Change Alarm 4
Relay Program Event O/P 2
Relay Program End O/P
Relay Load Failure
Relay Heater Failure
Relay SSR Failure
Logic OutputĀ Fitted Unconfigured
Triac Output Fitted Unconfigured
DC Retransmission Output Unconfigured (See Note 1)
None |
COMMS |
A2
AM
AE
F2
FM
FE
Y2
YM
YE
XX |
RS232 Fitted Unconfigured
RS232 Modbus Protocol
RS232 EI-Bisynch Protocol
RS422 Fitted Unconfigured
RS422 Modbus Protocol
RS422 EI-Bisynch Protocol
RS485 Fitted Unconfigured
RS485 Modbus Protocol
RS485 EI-Bisynch Protocol
None |
MANUAL |
ENG |
English |
SENSOR INPUT |
1
2
3
4
5
6
7
8
A
B
C
D
E
F
G
J
K
L
M
N
P
R
S
T
V
W
X
Y
Z |
Ni/Ni18%Mo Thm'cple
Pt20%Rh/Pt40%Rh Thm'cple
W/W26%Re Thm'cple
W/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
W5%Re/W26%Re Thm'cple
Pt10%Rh/Pt40%Rh Thm'cple
Exegen K80 I.R.Pyrometer
4 to 20mA Linear
B Thm'cple Pt/Pt30%Rh -6%Rh
*C Thm'cple W5%Re/W26%Re
D Thm'cple W3%Re/W25%Re
E Thermocouple
-100 to +100mV Linear
1 to 5Vdc Linear
J Thermocouple
K Thermocouple
L Thermocouple
-12 to 80mV Linear
N Thm'cple Nicrosil/NiSil
Platinel II Thm'cple
R Thm'cple Pt/Pt13%Rh
S Thm'cple Pt/Pt10%Rh
T Thermocouple
0 to 10Vdc Linear
0 to 5Vdc Linear
Non Standard
0 to 20mA Linear
RTD/PT100 DIN 43760 |
MINIMUM RANGE |
* |
User defined range |
MAXIMUM RANGE |
* |
User defined range |
DISPLAY UNITS |
C
F
K
X
|
Centigrade
Fahrenheit
Kelvin
Blank
Default Config |
OPTIONS 1 |
XX
DP |
None
Direct Acting PID Ctrl. |
OPTIONS 2 |
XX
PD |
None
Power Feedback Disabled |
OPTIONS 3 |
XX
CF
CW
CL
CO |
None
Fan Cooling
Water Cooling
Oil Cooling
On/Off Cooling |
OPTIONS 4 |
XX
MD
RD
MR |
None
Auto/Man Button Disabled
Run/Hold Button Disabled
Auto/Man & Run/Hold Disabled |
OPTIONS 5 |
XX
HD
HR
HT |
None
Dwell Time In Hours
Ramp Rate in Units/Hour
Dwell & Ramp in Hours |