392 Circular Chart Recorder Configurator
392 Circular Chart Recorder Configurator
Field
Option Description
Code
1
CHANNELS

01 Number of Channels
02 Number of Channels
03 Number of Channels
04 Number of Channels

1
2
3
4
2
POWER SUPPLY 110/120 Vac
220/240 Vac
1
3
3
CH 1 INPUT SIGNAL Universal
4-20mAdc (250ohm Shunt)
1
3
4
CH 2 INPUT SIGNAL None
Universal
4-20mAdc (250ohm Shunt)
0
1
3
5
CH 3 INPUT SIGNAL None
Universal
4-20mAdc (250ohm Shunt)
0
1
3
6
CH 4 INPUT SIGNAL None
Universal
4-20mAdc (250ohm Shunt)
0
1
3
7
INPUT ISOLATION
*See note 1
All Channels Isolated (Default)
0
8
OUTPUT RELAYS
*See note 2
None
Four Relays (One Card)
Eight Relays (2 Cards)
0
4

8
9
CONTROL LOOPS
*See note 3
None
Current Adjust 4-20mAdc (CAT)
Duration Adjust, Relay (DAT)
Duplex CAT
0
1
2
3
10
CONTROL LOOPS
*See note 3
None
Current Adjust 4-20mAdc (CAT)
Duration Adjust, Relay (DAT)
Duplex CAT
0
1
2
3
11
SETPOINT GENERATOR None
Setpoint Generator
0
1
12
CASE & MOUNTING NEMA 3 Panel
NEMA 3 Pipe
0
1
13
DOOR LOCK No Door Lock
Door Lock
0
1
14
TRANSDUCER POWER SUPPLY
*Must choose 1 shunt per channel
None
Trans PSU(4Ch 25Ma 100V)
0
1
15
TOTALIZERS (SOFTWARE) None
One Totalizer
Two Totalizers
Three Totalizers
Four Totalizers
0
1
2
3
4
16
TOTALIZER COUNTER OUTPUTS
*See note 4
None
One (with two relays)
Two (with two relays)
Three (with four relays)
Four (with four relays)
0
1
2
3
4
17
CUSTOM CURVE None
Custom Curve
0
1
18
DERIVED VARIABLE None
DV One Ch (With 9 DV Calc)
DV Two Ch (With 9 DV Calc)
0
1
2
19
ANALOG RETRANSMISSION
*See note 2
None
Two Retrans (One Output Card)
Four Retrans (Two Output Cards)
0
2
4
20
EVENT (CONTACT) INPUTS
*See note 2
None
Eight Event Inputs
Sixteen Event Inputs
0
1
2
21
RS422 COMMUNICATIONS none
0
22
FIXED FIELD Default
0
23
WINDOW MATERIAL Glass
Acrylic
0
1
24
FIXED FIELD Default
0
25
EVENT PEN OPTION None
0
26
FIXED FIELD Default
0
27
FIXED FIELD Default
00
28
FIXED FIELD Default
0
29
FIXED FIELD Default
0
30
FIXED FIELD Default
0
31
CHART SUPPLIED WITH INSTRUMENT 12 HR/50 Division
12 HR/80 Division
12 HR/100 Division
12 HR/150 Division
24 HR/50 Division
24 HR/60 Division
24 HR/70 Division
24 HR/80 Division
24 HR/100 Division
24 HR/150 Division
7 Day / 50 Division
7 Day / 60 Division
7 Day / 70 Division
7 Day / 80 Division
7 Day / 100 Division
7 Day / 150 Division
12HR/50
12HR/80
12HR/100
12HR/150
24HR/50
24HR/60
24HR/70
24HR/80
24HR/100
24HR/150
7DAY/50
7DAY/60
7DAY/70
7DAY/80
7DAY/100
7DAY/150

Note 1: Input channel isolation is now standard on all 392’s
Note 2: The 392 has a three (3) option board limitation (i.e. 4 relays + 4 retrans = 3 output boards).
Note 3: The CAT option utilizes one option board. The DAT option utilizes 4 relays (1 board). Be advised that you cannot order 2 relay boards (8 relays) + DAT option. Call factory for additional clarification.
Note 4: You must order the totalizer functionality if you want to utilize the totalizer counter outputs.